The City of El Dorado has adopted the following codes to regulate construction within the city:

 

2006 International Building Code including Appendix Chapters C, E, F, H, I, J

Amendments:     

All structures with a floor area of more than 60 square feet require a building permit.

All fences require a building permit.

Building Official can set time limit for any permit.

All structures must be anchored to the ground to meet the requirements of the code.

Wood sill plates must be naturally durable or preservative treated wood.

 

2006 International Residential Code including Appendix Chapters E, G, H, J, K, M

Amendments:

Design criteria established                                  Ground Snow Load:                            15 psf

                                                                                Wind Speed:                                          90 mph

                                                                                Seismic Design Category:                    A

                                                                                Weathering:                                          Severe

                                                                                Frost Line Depth:                                30 inches

                                                                                Termite:                                                Moderate to Heavy

                                                                                Winter Design Temp:                           7

                                                                                Ice Barrier

                                                                                  Underlayment Required:                  No

                                                                                Flood Hazards:                                     FIRM Map Dated                                                                                                                                                                 June 20, 2001,        

                                                                                                                                                  or as updated

                                                                                Air Freezing Index:                               0-1000

                                                                                Mean Annual Temp:                            55-60

All structures with a floor area of more than 60 square feet require a building permit.

All fences require a building permit.

Building Official can set time limit for any permit.

All structures must be anchored to the ground to meet the requirements of the code.

Wood sill plates must be naturally durable or preservative treated wood

 

2006 Uniform Plumbing Code

Amendments:

If there are conflicts between this code and other codes adopted by the City of El Dorado, the Building Official shall have the authority to determine if both codes are acceptable.

Permit and plan review fees shall be assessed in accordance with the Municipal Code.

Plastic pipe can be tested with air.

Code clarification: 316.1.6 PVC pipe and fittings shall be cleaned and joined with primer and solvent cement. ONE STEP CEMENT IS NOT ALLOWED!!!

 

2006 Uniform Mechanical Code

Amendments:

If there are conflicts between this code and other codes adopted by the City of El Dorado, the Building Official shall have the authority to determine if both codes are acceptable.

 

2008 National Electric Code

Amendments:

Interior nonmetallic sheathed cable shall be secured by insulated fasteners, insulated staples, cable ties or straps.

GFCI protection is not required for a sump pump or sewage ejector pump if connected to a single receptacle supplied by a dedicated branch circuit.

AFCI protection is required at dwelling unit bedrooms only.

The NEC does not address unfused service cable inside the house. See Building Official for service entrance requirements as established by the City of El Dorado.

 

2006 International Fire Code

See Fire Marshall for amendments to the fire code.

 

There are additional administrative amendments to each of the above codes. The ordinances that adopt the codes are available in there entirety at your request. Code books are available for review in the office of the Building Official.